Ga vs Gb vs Gc: Choosing Inspection Cameras for Hazardous Areas

By Vivek Rohra 6 minute read
Inspection Cameras for Hazardous Areas

Equipment Protection Levels (EPLs) tell buyers how strongly equipment is protected against becoming an ignition source in an explosive atmosphere. For gas hazards, Ga provides very high protection, Gb high protection and Gc enhanced protection. They are normally associated with Zones 0, 1 and 2, respectively.

That difference matters when choosing a videoscope or inspection camera for a refinery, chemical plant or other classified location. A camera approved for Gc cannot be assumed suitable for Zone 1 or Zone 0. The full Ex marking, site classification and approved configuration still control where it may be used.

For the broader relationship between areas and equipment categories, see AIT's ATEX ratings for inspection cameras.

Quick answer: Ga is typically suitable for gas Zones 0, 1 and 2; Gb for Zones 1 and 2; and Gc for Zone 2 only, provided every other part of the approval also matches. A higher protection level does not make gas group, temperature class or certificate conditions optional.

Ga, Gb and Gc Mean Different Levels of Ignition Protection

The letters follow the IEC 60079 equipment protection system. The capital G identifies an explosive gas atmosphere; the lowercase letter describes protection against becoming an ignition source under different operating and fault conditions. Those conditions are the reason a Zone 0 instrument needs a different approval from one intended for Zone 2.

GaVery high protection

Designed so it is not an ignition source during normal operation, expected malfunctions or rare malfunctions. Typically required for gas Zone 0.

GbHigh protection

Designed so it is not an ignition source during normal operation or expected malfunctions. Typically associated with gas Zone 1.

GcEnhanced protection

Designed not to ignite the atmosphere during normal operation, with additional protection possible for specified regular expected events. Typically associated with gas Zone 2.

Descriptions such as "two faults" and "one fault" can help with a basic explanation, but the IEC definition considers expected and rare malfunctions, not a blanket promise about any possible equipment failure. The U.S. Coast Guard's EPL explanation describes these protection levels using the IEC 60079-0 definitions.

Which EPL Is Suitable for Zone 0, Zone 1 or Zone 2?

The classified area is assigned by the facility's responsible personnel. It describes how often an explosive gas atmosphere can exist. EPL describes the protection built into the equipment. These two classifications are related, but they answer different questions.

Area
Minimum gas EPL
Usual ATEX category
Explosive gas atmosphere
Zone 0
Ga
1G
Present continuously, for long periods or frequently. Gc or Gb equipment alone does not meet the usual Zone 0 protection requirement.
Zone 1
Gb or Ga
2G or 1G
Likely occasionally during normal operation. A Gc-only camera is not a substitute for the required protection level.
Zone 2
Gc, Gb or Ga
3G, 2G or 1G
Unlikely in normal operation, or present only briefly if it occurs. Equipment still needs the correct gas group and temperature class.

ATEX Categories 1G, 2G and 3G commonly correspond to Ga, Gb and Gc in IEC-based Ex markings. They are not interchangeable proof of certification under every regulatory scheme. Check the approval intended for the country of use, the certificate and any conditions attached to it.

Site classification comes first: A clean, empty or temporarily shut-down vessel is not automatically declassified. The facility's approved hazard assessment governs the work, even when no flammable vapor is visible.

Where to Find the EPL on a Camera's Ex Marking

The EPL usually appears at the end of an IEC-based Ex marking. AIT's hazardous-area videoscope provides a useful real-world example:

II 3 G Ex ic nA IIC T4 Gc

The final Gc identifies its gas equipment protection level. The rest of the marking remains relevant:

II 3 GGroup II, Category 3 for gas

Identifies the category and gas-atmosphere application associated with this Zone 2 instrument.

Ex ic nAProtection construction

Names the explosion-protection techniques used for the approved equipment design.

IIC T4 GcGas, temperature and EPL

Identifies the gas group, T4 surface-temperature class and Gc protection level. None replaces the others.

For how the full sequence is read, see AIT's ATEX marking explanation. The IIA, IIB and IIC hierarchy is covered separately in its gas-group comparison.

What Happens When the Probe Enters a Different Classified Area?

For a portable inspection camera, the operator and probe may not be in the same atmosphere. A technician could stand near a vessel opening in an area classified as Zone 2 while the probe enters an internal space with a different classification. That is a separate equipment-acceptance problem from choosing the correct probe length.

Inspection arrangement
What the EPL tells you
What still needs confirmation
Camera and probe remain within Zone 2
Gc may meet the zone's minimum gas EPL.
Gas group, T-class, ambient limits and the complete approved configuration.
Handset in Zone 2; probe enters Zone 1
A Gc marking on the system does not establish Zone 1 suitability for the inserted probe.
Specific approval for the portion entering Zone 1 and the complete installation or operating arrangement.
Handset in Zone 2; probe enters Zone 0
Ga-level protection is normally required for equipment exposed to Zone 0.
Approval of the complete equipment arrangement, including any separately rated part or separation element.

IEC 60079-26 addresses Ex equipment containing parts with different protection levels across a hazardous-area boundary. It does not mean that a standard Gc videoscope can be inserted into Zone 0 by keeping its handset outside. Such an arrangement needs its own documented approval and facility authorization. The IEC 60079-26 standard overview explains the scope of this special case.

How AITVS Fits a Gc Inspection Requirement

AIT VideoScope AITVS hazardous-area articulating inspection camera

AIT VideoScope (AITVS)

AITVS is AIT's articulating videoscope for applicable ATEX Zone 2 and North American Class I Division 2 gas or vapor applications. Its published ATEX marking ends in Gc and includes IIC T4, with separate approvals for the relevant regulatory systems.

It offers 4-way articulation and several probe-diameter and insertion-length options. The exact configuration and safe-use restrictions must be checked before site approval or quotation. AITVS is not approved as a Zone 0 or Zone 1 camera on the basis of its Gc marking.

Certification is configuration-specific

A 4-way articulating probe, battery and display may be the right inspection tools, but the site still needs to accept the marked system, permitted components and operating conditions. Separate testing claims do not raise a Gc approval to Gb or Ga.

Why Similar Inspection Cameras Can Get Different Site Decisions

Two videoscopes can have comparable imaging, insertion diameter and reach while carrying different Ex approvals. That difference changes where they are permitted to work. A purchase comparison that starts and ends with camera resolution may miss the site restriction that decides whether the instrument can be used.

Correct EPL, wrong gas groupThe equipment remains unsuitable

Gb protection does not compensate for a gas-group marking that fails to cover the site atmosphere.

Correct EPL, wrong T-classSurface limits still apply

An otherwise suitable Gc camera can be excluded by an incompatible temperature class.

North American approvalsSeparate classification rules

Class I Division 2 approval does not automatically establish Ga, Gb or Gc suitability. Each approval needs to match the jurisdiction.

For North American gas-group details, AIT also explains Class I Division 2 Groups A, B, C and D. A site that has standardized on ATEX or IECEx should use its own specified approval requirements, not a label translated by assumption.

The Classified Boundary Does Not Appear in the Inspection Image

The same camera can face a different decision when the inspection moves a few feet.

A probe can pass through a small opening and show a clear image while the surrounding area stays visually unchanged. Yet the site classification may differ across that opening. If the inserted equipment enters an area requiring Gb or Ga protection, a Gc-only videoscope does not become acceptable because the operator remains outside.

For planned shutdowns, tank entries and process inspections, that distinction is worth settling before the access window opens. Otherwise the team may have a working camera, an accessible target and no approved way to make the inspection.

Frequently Asked Questions

01

Can AIT provide ATEX conformity documents before purchasing?

AIT can review available approval documentation for the quoted AITVS configuration.

02

Can AIT recommend another camera if our facility requires Gb protection?

AIT can review your site requirements and discuss suitable equipment options without assuming Gc equipment meets Gb requirements.

03

Can I arrange a product demonstration before ordering?

Contact AIT to discuss demonstration availability and your facility's safety requirements.

04

Can I order a different probe length for an existing AITVS?

AIT can verify available configurations and whether your requested arrangement is approved.

05

Can replacement batteries or accessories affect hazardous-area approval?

Yes, replacement components must meet the conditions of the approved system configuration.

Can Your Camera Enter the Area You Need to Inspect?

Recommended Products

AITVS explosion-proof-rated video borescope with handset and 5 inch display

AIT VideoScope (AITVS)

View Product
AIT K Series HD Videoscope with Motor-Driven Articulation

AIT K Series HD Videoscope with Motor-Driven Articulation

View Product
AIT TU Series Dual-Mode Ultraviolet/White HD Videoscope with Articulation

AIT T Series HD Videoscope with Mechanical Articulation

View Product

Related Guides

About the Author

Vivek Rohra

Vivek Rohra

LinkedIn

President of Advanced Inspection Technologies. With prior experience at Jefferies, Moelis & Company, Morgan Stanley, and J.P. Morgan, he brings deep expertise in aerospace, industrial, and healthcare sectors to the business of visual inspection.

Reviewed by AIT Inspection Team Last updated October 2026
Previous Next
20+
Years in Inspection
One source
Sales, Rentals & Repairs
7+
Industries Served
1 business day
Quote Response
Lifetime
Tech Support
Located In
The USA